Fluxus Meters Ultrasonic

20+ Annos Vestibulum Usus

pulsus ultrasonic aqua metri organi corporis

Description:

1. Nulla pars movens, minimal fluit instructio.Perferendis sagaciter.
2. Duplex canales ultrasonic temporis transiti sensoris ad altam accurate et certa operatione.
3. Metiri potest et repositione et antrorsum fluere ac refluere.
4. Activum Leak, furtum, regressum, metri damnum/tatione, rate fluxus, et altilium vitae indicationem
5. Supra 15 annos fasciae vitae.
6. IP 68 consilio, longtime sub aqua laborat.
7. Latin output is RS485, Lora, NB-IoT, 4-20mA, Pulsus, GPRS libitum esse possunt.


Features

pluma-ico01

Nulla pars movens, minimal fluit instructio.Perferendis sagaciter.

pluma-ico01

Duplex canales ultrasonic temporis transiti sensoris ad altam accurate et certa operatione.

pluma-ico01

Metiri potest et repone et deinceps fluunt et refluunt.

pluma-ico01

Activa Leak, furtum, regressum, metri damnum/tatione, rate fluxus ac altilium vitae indicationem

pluma-ico01

Anno supra 15 pluteum vite.

pluma-ico01

IP 68 consilio, longtime sub aqua laborat.

pluma-ico01

Vexillum output est RS485, Lora, NB-IoT, 4-20mA, Pulsus, GPRS libitum esse possunt.

Specificaitons

Genera Ultrawater
Flow rate m³/h DN
50-2"
DN
65-2.5"
DN
80-3"
DN
100-4"
DN
150-6"
DN
200-8"
DN
250-10"
DN
300-12"
Q4 50 50 80 125 313 500 1250 1250
Q3 40 40 63 100 250 400 1000 1000
Q2 0.128 0.128 0.2 0.32 0.8 1.28 3.2 3.2
Q1 0.08 0.08 0.125 0.2 0.5 0.8 2 2
R=Q3/Q1 500 500 500 500 500 500 500 500
Maximilianus.Opus Pressura 1.6Mpa
Pressura damnum P16
Genus temperatus T50
Opus environment Temperature: -25℃~55℃, Umor: ≤100% (RH)
Electromagnetica convenientiae E2
Ostendere 9-bit LCD proponere.Ostentare totalzer, Ultra fluunt, error terror, fluunt directionem, output
Data Storage Potest repono data X annis, anno, mense et die
Output Modbus (baud rate:19200、9600、4800、2400);4-20mA, Pulsus, (default 2ml/pulsus)
Potentia copia DC3.6V (disponi lithium batteries) ≥ 15 years
Pipe Range DN50-DN300
IP Gradus IP68
Sagaciter classis Classis 1
Processus nexum Flange

cura curvo

Ultrawater Serials Ultrasonic Aqua Meter2

Dimension

Ultrawater Serials Ultrasonic Aqua Meter4
Genera Ultrawater
Nominal Diameter (mm) 50 65 80 100 150 200 250 300
(inch) 2 25 3 4 6 8 10 12
Fistula L- longitudo (mm). 200 200 225 250 300 350 449 499
B- latitudo (mm) 165 185 200 220 285 340 406 489
H- altitudo (mm). 194 210 210 223 282 332 383 456
h- altitudo (mm) 40 90 90 103 140 165 203 245
Pondus (mm) 9 11.5 13 15 32 45 68 96

  • Previous:
  • Deinde:

  • Epistulam tuam nobis mitte;

    Epistulam tuam hic scribe et mitte nobis

    Epistulam tuam nobis mitte;